| Refrigerated Air Drier Application: The ambient air given off by any compressor always contains water vapour. This depends on the ambient temperature and the relative humidity. When air is compressed, the volume decreases proportionally. This results in condensate formation. Condensate causes corrosion in compressed air pipe line, increases tool wear, faults in pneumatic controls, delayed response time, expensive down time, etc. Compressed air driers are used to separate the condensate and contaminants. ELGI offers the best and reliable solution with the Airmate driers. Benefits: | Low pressure drop : 0.2Kg/cm2 Heat Exchanger : Efficient heat transfer, Non fouling, no pre Filter. Lowest operating cost Non cyclic : Continuous operation, low wear and tear Increased durability of the drier Cooling : Air cooled/Water Cooled Designs available Tropicalised machine : Suitable for high ambient conditions | 
Air drier
| Specifications: | Model | Flow | Max Pressure (Bar) | Electrical | Dimension in mm | Weight in Kgs | Cooling media | | (cfm) | m3/min | Volts | HZ | Phase | Length | Breath | Height | | ELRD010 | 10 | 0.28 | 16 | 230 Volts | 50 Hz | Single | 360 | 475 | 550 | 45 | Air | | ELRD020 | 20 | 0.57 | 16 | 230 Volts | 50 Hz | Single | 360 | 475 | 550 | 45 | Air | | ELRD030 | 30 | 0.85 | 16 | 230 Volts | 50 Hz | Single | 360 | 475 | 550 | 47 | Air | | ELRD040 | 40 | 1.13 | 16 | 230 Volts | 50 Hz | Single | 360 | 475 | 550 | 47 | Air | | ELRD050 | 50 | 1.42 | 16 | 230 Volts | 50 Hz | Single | 500 | 600 | 730 | 84 | Air | | ELRD064 | 64 | 1.81 | 16 | 230 Volts | 50 Hz | Single | 500 | 600 | 730 | 84 | Air | | ELRD085 | 85 | 2.41 | 16 | 230 Volts | 50 Hz | Single | 700 | 700 | 830 | 95 | Air | | ELRD105 | 105 | 2.97 | 16 | 230 Volts | 50 Hz | Single | 700 | 700 | 830 | 121 | Air | | ELRD126 | 126 | 3.57 | 16 | 230 Volts | 50 Hz | Single | 700 | 700 | 830 | 135 | Air | | ELRD191 | 191 | 5.41 | 16 | 230 Volts | 50 Hz | Single | 700 | 700 | 830 | 135 | Air | | ELRD227 | 227 | 6.43 | 16 | 230 Volts | 50 Hz | Single | 700 | 700 | 830 | 140 | Air | | ELRD267 | 267 | 7.56 | 16 | 230 Volts | 50 Hz | Single | 900 | 900 | 1230 | 200 | Air | | ELRD345 | 345 | 9.77 | 16 | 230 Volts | 50 Hz | Single | 900 | 900 | 1230 | 200 | Air | | ELRD450 | 450 | 12.74 | 16 | 415 Volts | 50 Hz | Three | 800 | 1000 | 1350 | 250 | Air | | ELRD500 | 500 | 14.16 | 16 | 415 Volts | 50 Hz | Three | 800 | 1000 | 1350 | 250 | Air/Water | | ELRD600 | 600 | 16.99 | 16 | 415 Volts | 50 Hz | Three | 900 | 1200 | 1475 | 275 | Air/Water | | ELRD750 | 750 | 21.24 | 16 | 415 Volts | 50 Hz | Three | 900 | 1200 | 1475 | 375 | Air/Water | | ELRD900 | 900 | 25.48 | 16 | 415 Volts | 50 Hz | Three | 900 | 1200 | 1475 | 425 | Air/Water | | ELRD1100 | 1100 | 31.15 | 16 | 415 Volts | 50 Hz | Three | 900 | 1200 | 1475 | 425 | Air/Water | | ELRD1254 | 1254 | 35.51 | 16 | 415 Volts | 50 Hz | Three | 1600 | 1100 | 1400 | 1000 | Water | | ELRD1552 | 1552 | 43.95 | 12.5 | 415 Volts | 50 Hz | Three | 1600 | 1100 | 1400 | 1200 | Water | | ELRD1750 | 1750 | 49.55 | 12.5 | 415 Volts | 50 Hz | Three | 1800 | 1100 | 1400 | 1500 | Water | * Higher capacity models are also available on request. Performance data are measured at 7 bar and inlet Temperature 45 Degree C Ambient Temperature 35 Degree C. Pressure dew point+3 Degree C. For different operating conditions, please contact the nearest ELGI outlet. Drier of Higher capacities are also available. Details on request. Due to continuous engineering improvements, specifications are subject to change. |